External Control Functions of the SP-3U/6U Series (Part 2)

2024-11-11

1. Setting Voltage and Current via External Control

Selecting the Input Reference Voltage: 5 V or 10 V

Use an external voltage input (0–5 V) or an external resistor (0–5 kΩ or 0–10 kΩ) to remotely adjust the voltage and current settings.

1.png

Controlling the Output with an External High or Low Level

On the external control settings screen, if Output On is set to High, applying a high level to the Pin 1 (EXT-ON) terminal turns the power supply output ON; applying a low level turns the output OFF.

Conversely, if Output On is set to Low, the logic is reversed.

2.png


2. Output Inhibit Function

Used with the External Control Function

3.png

On the external control settings screen, Inhibit can be set to High or Low.

If set to High, applying a high level between the Pin 7 (INHIBIT) and Pin 9 (DGND) terminals turns the power supply output OFF.

Conversely, if set to Low, the logic is reversed.

44.png

Used as a Global Function

4.png

This function is multiplexed onto Pin 7. Set external control to Disable, and set Inhibit to High.

On the Inhibit Output screen, select Global. Then configure the voltage and current parameters and enable the output on the main screen (or on another function screen).

  • If a high level is applied to Pin 7, the power supply output turns OFF.
  • If a low level is applied, the power supply outputs normally.

Conversely, if Inhibit is set to Low:

  • Applying a low level to Pin 7 turns the output OFF.
  • Applying a high level allows the power supply to output normally.

3. A/B Switching Function

5.png

Enter this screen and click Enable. This function lets you configure two sets of voltage and current parameters (A and B) and switch the output using the ON/OFF key.

Apply a high or low level to Pin 13 on the external control terminal board to switch between parameter set A and parameter set B. The voltage and current setting parameters change simultaneously.

By default, a low level selects parameter set A, and a high level selects parameter set B.

6.png

PreviousNo!

NextExternal Control Functions of the SP-3U/6U Series (Part 1)2024-11-11

News

About us
Product
Brand
News
Contact

Hotline:021-37707737

Scan

Links: 上海渤翰电子科技有限公司 | 上海渤翰电子科技有限公司 | 百度

website :Hongqi Copyright @ Shanghai Bohang Electronic Technology Co., Ltd 沪ICP备16002712号-1

沪公网安备 31011702002178号

top